  • Current mVSA configuration:
  • Blood Pressure + Pulse
  • seca BIA Module
  • Without SpO2 module
  • GENIUS temperature modul
Request Pricing Request a Demonstration
Your current configuration is not available. Please adjust your configuration.
Quick Overview

Precision

  • Basic
  • Advanced
  • Premium

Key-Technical Data

Blood pressure measurement methodOscillometric, deflation or inflation measurement
Blood pressure measurement timeNormal: 15 - 20 sec / max. 90 sec (adults)
Temperature measurement response time< 2 sec.
Temperature measuring methodin Ear

Scope of Delivery

  • 1x GENIUS 2 Tympanic probe covers (Box á 96 pcs)
  • Removable Smart Bucket with integrated Vital Signs Moduls: for blood pressure/Temp measurement
  • One licence of seca analytics 115
  • GENIUS 2 Tympanic in-Ear thermometer
  • Monitor with power cable
  • seca BIA measuring mat
  • seca cuff (size M)
  • seca measuring tape
Description

Product Properties

  • Conventional measurement of vital signs of blood pressure, SpO2, pulse rate and temperature.
  • Fast and easy assessment of body composition, e. g., fat mass, body water and muscle mass.
  • Easy integration into any EMR system and connection to seca measuring systems and scales.
  • Easy-to-understand graphic presentation of measurement results on the touchscreen monitor.
  • Internal storage for results of approximately 70,000 measurements.
  • Integrated replaceable rechargeable lithium ion battery in the monitor.

The world’s first medical Vital Signs Analyzer with BIA measurement.

You can now measure more parameters in a routine check and broaden your diagnostic and therapeutic options through the combined determination of BIA and vital signs. The highperformance software communicates with any network and guarantees the error-free transmission of all measurement values to your EMR system. seca offers the spot-check-monitor with the Bioelectrical Impedance Analysis function in many interesting configurations as a one-of-a-kind device worldwide. An update for the seca mBCA 525 is also possible across all product ranges.

Precision

  • Basic
  • Advanced
  • Premium

Key-Technical Data

Blood pressure measurement methodOscillometric, deflation or inflation measurement
Blood pressure measurement timeNormal: 15 - 20 sec / max. 90 sec (adults)
Temperature measurement response time< 2 sec.
Temperature measuring methodin Ear

Functions and Properties

Scope of Delivery

  • 1x GENIUS 2 Tympanic probe covers (Box á 96 pcs)
  • Removable Smart Bucket with integrated Vital Signs Moduls: for blood pressure/Temp measurement
  • One licence of seca analytics 115
  • GENIUS 2 Tympanic in-Ear thermometer
  • Monitor with power cable
  • seca BIA measuring mat
  • seca cuff (size M)
  • seca measuring tape
Technical Data

Technical Data

Display7" touchscreen display
BIA measuring period30 seconds
BIA measuring frequency1; 2; 5; 10; 20; 50; 100; 200; 500 kHz
BIA measuring method8-point Bioelectrical Impedance Analysis
BIA measurement segmentsRight arm, left arm, right leg, left leg, right half of body, left half of body, torso
BIA measuring electricity100 µA
BIA Moduleseca BIA Module
Blood pressure measurement range - deflationpSYS: 25 - 280 mmHg pDIA: 10 - 220 mmHg pMAP: 15 - 260 mmHg
Blood pressure measurement range - inflationpSYS: 77 - 200 mmHg pDIA: 45 - 190 mmHg pMAP: 56 - 193 mmHg
Blood pressure measurement accuracy - deflation (clinical validated)Mean deviation systole 0.39 mmHg; Standard deviation systole 2.57 mmHg; Mean deviation diastole 0.43 mmHg; Standard deviation diastole 1.73 mmHg
Blood pressure measurement accuracy - inflation (clinical validated)Mean deviation systole 0.94 mmHg; Standard deviation systole 3.84 mmHg; Mean deviation diastole 0.57 mmHg; Standard deviation diastole 3.17 mmHg
Blood pressure measurement methodOscillometric, deflation or inflation measurement
Blood pressure measurement certaintyExcess pressure limit 300 mmHg;
automatic pressure release at > 300 mmHg
Blood pressure measurement timeNormal: 15 - 20 sec / max. 90 sec (adults)
Blood pressure pulse rate accuracymax. +/- 3 bpm
Blood pressure pulse rate range - deflation30 - 240 bpm
Blood pressure pulse rate range - inflation45 - 200 bpm
Net weight0.6 sts
3.7 kg
Measurement accuracy at target temperature: 25 °C (77 °F)Target temperature: 33 °C 42 °C (91.4 °F 107.6 °F) ± 0.2 °C ( ± 0.4 °F)
Measurement accuracy at ambient temperature: 16 °C - 33 °C (60.8 °F - 91.4 °F)Target temperature: 36.7 °C 38.9 °C (98.1 °F 102 °F) ± 0.1 °C ( ± 0.2 °F)
Measuring mat width170 mm
Measuring mat height20 mm
Measuring mat depth783 mm
Product width252 mm
Product height262 mm
Product depth278 mm
PortsEthernet
USB 2.0
Wi-Fi
SpO2 moduleWithout SpO2 module
Power supplyBuilt-in power adapter, internal rechargeable lithium-ion battery
Temperature measuring range33 - 42 °C
Temperature measurement response time< 2 sec.
Temperature measuring methodin Ear
Temperature moduleGENIUS temperature modul

Functions and Properties

  • 8 point measurement
  • EMR ready
  • BIA measurement
  • Blood pressure measurement
  • Mobile use
  • Temperature measuement