0121 643 9349
shop hotline
new
seca mVSA 535 - Spot-check-monitor for customised configuration #0
seca mVSA 535 - Spot-check-monitor for customised configuration #1
seca mVSA 535 - Spot-check-monitor for customised configuration #2
seca mVSA 535 - Spot-check-monitor for customised configuration #3

seca mVSA 535

Product Number 535 1030 001

Spot-check-monitor for customised configuration

seca mVSA 535
Delivery Time on Request
  • Current mVSA configuration:
  • Blood Pressure + Pulse
  • Without BIA Module
  • Without SpO2 module
  • GENIUS temperature modul
Request Pricing Request a Demonstration
Your current configuration is not available. Please adjust your configuration.
Quick Overview

Precision

  • Basic
  • Advanced
  • Premium

Key-Technical Data

Blood pressure measurement methodOscillometric, deflation or inflation measurement
Blood pressure measurement timeNormal: 15 - 20 sec / max. 90 sec (adults)
Temperature measurement response time< 2 sec.
Temperature measuring methodin Ear

Scope of Delivery

  • 1x GENIUS 2 Tympanic probe covers (Box á 96 pcs)
  • Removable Smart Bucket with integrated Vital Signs Moduls: for blood pressure/Temp measurement
  • GENIUS 2 Tympanic in-Ear thermometer
  • Monitor with power cable
  • seca cuff (size M)
Description

Product Properties

  • Conventional measurement of vital signs of blood pressure, SpO2, pulse rate and temperature.
  • Fast and easy assessment of body composition, e. g., fat mass, body water and muscle mass.
  • Easy integration into any EMR system and connection to seca measuring systems and scales.
  • Easy-to-understand graphic presentation of measurement results on the touchscreen monitor.
  • Internal storage for results of approximately 70,000 measurements.
  • Integrated replaceable rechargeable lithium ion battery in the monitor.

The world’s first medical Vital Signs Analyzer with BIA measurement.

You can now measure more parameters in a routine check and broaden your diagnostic and therapeutic options through the combined determination of BIA and vital signs. The highperformance software communicates with any network and guarantees the error-free transmission of all measurement values to your EMR system. seca offers the spot-check-monitor with the Bioelectrical Impedance Analysis function in many interesting configurations as a one-of-a-kind device worldwide. An update for the seca mBCA 525 is also possible across all product ranges.

Precision

  • Basic
  • Advanced
  • Premium

Key-Technical Data

Blood pressure measurement methodOscillometric, deflation or inflation measurement
Blood pressure measurement timeNormal: 15 - 20 sec / max. 90 sec (adults)
Temperature measurement response time< 2 sec.
Temperature measuring methodin Ear

Functions and Properties

Scope of Delivery

  • 1x GENIUS 2 Tympanic probe covers (Box á 96 pcs)
  • Removable Smart Bucket with integrated Vital Signs Moduls: for blood pressure/Temp measurement
  • GENIUS 2 Tympanic in-Ear thermometer
  • Monitor with power cable
  • seca cuff (size M)
Technical Data

Technical Data

Display7" touchscreen display
BIA ModuleWithout BIA Module
Blood pressure measurement range - deflationpSYS: 25 - 280 mmHg pDIA: 10 - 220 mmHg pMAP: 15 - 260 mmHg
Blood pressure measurement range - inflationpSYS: 77 - 200 mmHg pDIA: 45 - 190 mmHg pMAP: 56 - 193 mmHg
Blood pressure measurement accuracy - deflation (clinical validated)Mean deviation systole 0.39 mmHg; Standard deviation systole 2.57 mmHg; Mean deviation diastole 0.43 mmHg; Standard deviation diastole 1.73 mmHg
Blood pressure measurement accuracy - inflation (clinical validated)Mean deviation systole 0.94 mmHg; Standard deviation systole 3.84 mmHg; Mean deviation diastole 0.57 mmHg; Standard deviation diastole 3.17 mmHg
Blood pressure measurement methodOscillometric, deflation or inflation measurement
Blood pressure measurement certaintyExcess pressure limit 300 mmHg;
automatic pressure release at > 300 mmHg
Blood pressure measurement timeNormal: 15 - 20 sec / max. 90 sec (adults)
Blood pressure pulse rate accuracymax. +/- 3 bpm
Blood pressure pulse rate range - deflation30 - 240 bpm
Blood pressure pulse rate range - inflation45 - 200 bpm
Net weight0.4 sts
2.7 kg
Measurement accuracy at target temperature: 25 °C (77 °F)Target temperature: 33 °C 42 °C (91.4 °F 107.6 °F) ± 0.2 °C ( ± 0.4 °F)
Measurement accuracy at ambient temperature: 16 °C - 33 °C (60.8 °F - 91.4 °F)Target temperature: 36.7 °C 38.9 °C (98.1 °F 102 °F) ± 0.1 °C ( ± 0.2 °F)
Product width252 mm
Product height262 mm
Product depth278 mm
PortsEthernet
USB 2.0
Wi-Fi
SpO2 moduleWithout SpO2 module
Power supplyBuilt-in power adapter, internal rechargeable lithium-ion battery
Temperature measuring range33 - 42 °C
Temperature measurement response time< 2 sec.
Temperature measuring methodin Ear
Temperature moduleGENIUS temperature modul

Functions and Properties

  • EMR ready
  • Blood pressure measurement
  • Mobile use
  • Temperature measuement
  • Touch-display
Accessories

Accessories

System

System

This product is compatible with all EMR systems and with the following EMR validated seca products.